We make thyristorised drive control panel board
upto 150 TPH . |
Fether touch control will be provided for smooth
operation of plant. |
|
General
feature:- |
|
User friendly |
|
As per M.O.S.T. |
|
Fully auto microprocessor based
technology |
|
Best quality of product |
|
Easy to operate |
|
|
|
|
Technical
specification for Drum mix control panel board
:- |
Indication |
R,Y,B Phase indication will be provided.
Control ON indication will be provided. Motor ON indication will be provided for each motor.
Empty Bin indication will be provided
for each Bin. |
Meter |
A.C. voltmeter will be provided to measure main voltage between phase by voltage selector switch and A.C. amperemeter will be provided to measure electrical load on each phase by ampere selector switch.
A.C. amperemeter will be provided for all motors. |
Over
Load |
Bi - Metal Thermal Over Load relay will be
provided for protection of each A.C. motor. |
MCB |
M C B will be provided for each A.C. motor safety and protection. |
MCCB |
M C C B will be provided for main supply. |
Emergency
Stop |
Stay put type emergency stop will be provided to stop the plant immediately in case of accident. |
Setting
of Speed |
Potential pot will be provided for each Bin’s motor & Asphal’s pump, Filler’s valve.
Setting of speed can also be controlled by
totalizer. |
|
|
Display System :- |
|
Product Rate |
Display shows the present Ton /
Hour (TPH) capacity of the plant. |
Display shows :- |
|
Set percentage of
each Bin |
|
Master setting |
|
Set & actual
aggregate TPH, percentage of Bitumen,
percentage of filler |
|
Actual percentage & kg/min of
Bitumen and filler |
|
Percentage of set moisture |
|
|
Total |
Display shows |
|
total tones of Aggregate |
|
total kg of Bitumen |
|
total kg of Filler |
|
It also shows tones of Net mix
material. |
|
Temperature :- (
Microprocessor based Temperature controller) |
|
Display shows actual
temperature and set temperature of |
|
Bitumen Tank -1 temperature |
|
Bitumen Tank -2 temperature |
|
Mix material temperature |
|
Aggregate temperature |
|
|
High
temperature & Low temperature facilities
will be provided by control of Nozzle of
dryer burner. |
|
Mimic System :- |
Mimic
display shows indication
of running mode or OFF mode of any motor.
Whether the plant is in running mode or not is verified
from the mimic display. |
|
Hopper Function ( Micro
processor based ) :- |
Setting
of open time of Hopper, close time of Hopper,
hold on time of Hopper, |
It also shows display of above
parameter. |
Hopper can also be controlled
manually from feather touch control. |
|
Printer:- |
Wipro make printer will be
provided.
Printout facilities will be provided for current
material use for production.
In print out the following parameters will be
printed. |
|
Date |
Time |
|
Trip
No. |
Feeder
1 % |
Aggregate |
|
TPH |
Feeder
2 % |
Bitumen |
|
kg/min |
Feeder
3 % |
Filler |
|
kg/min |
Feeder
4 % |
Mix
Mat Temp. |
|
Celsius |
Moisture
% |
Exhaust
Temp. |
|
Celsius |
Filler
% |
Bit
Tank 1 Temp. |
|
Celsius |
Bitumen
% |
Bit
Tank 2 Temp. |
|
Celsius |
Master
% |
|
|
|
|
|
Totalizer :- |
|
Aggregate total Tons |
|
Bitumen total kgs |
|
Filler total kgs |
|
Total Mix Material Tons |
|